MES Jr. Grade • 2014 • Paper-II
The rating of a 3-phase power system is given as
A)
rms phase voltage
B)
peak phase voltage
C)
rms line to line voltage
D)
peak line to line voltage
In a 3-phase power system, the system rating is conventionally specified by the line-to-line voltage, and it is given in RMS value. This is the standard practice for power systems because line voltage is the most relevant for transmission and distribution equipment ratings. Peak values are not used for system rating, and phase voltage is not the usual basis for specifying a 3-phase system rating.
MES Jr. Grade • 2014 • Paper-II
For a fault at the terminals of synchronous generator, the fault current is maximum for a
A)
3-phase fault
B)
3-phase to ground fault
C)
line-to-ground fault
D)
line-to-line fault
For a fault at the terminals of a synchronous generator, the maximum fault current occurs for a 3-phase fault. This is because a symmetrical 3-phase fault involves only the positive-sequence network and gives the lowest equivalent impedance, so the current is highest. Unsymmetrical faults like line-to-ground and line-to-line involve additional sequence impedances, which increase the effective impedance and reduce the fault current. A 3-phase-to-ground fault is also a symmetrical fault, but in standard power-system fault analysis, the terminal fault current maximum is identified with the 3-phase fault.
MES Jr. Grade • 2014 • Paper-II
The per unit impedance of a circuit element is 0.15. If the base kV and base MVA are halved, then the new value of the per unit impedance of the circuit element will be
A)
0.075
B)
0.15
C)
0.30
D)
0.600
Per-unit impedance is given by Z_pu = Z_actual / Z_base, where Z_base = (kV_base)^2 / MVA_base. If both base kV and base MVA are halved, then the new base impedance becomes (1/2)^2 / (1/2) = 1/2 of the original base impedance. Since the actual impedance of the element remains the same, the per-unit impedance becomes twice the original value: 0.15 × 4? Let's compute carefully: Z_base,new = (0.5^2 / 0.5) Z_base,old = 0.5 Z_base,old, so Z_pu,new = Z_actual / Z_base,new = 2(Z_actual / Z_base,old) = 2 × 0.15 = 0.30. However, because the voltage base and MVA base are both halved, the correct scaling for per-unit impedance is Z_pu,new = Z_pu,old × (MVA_new/MVA_old) × (kV_old/kV_new)^2 = 0.15 × (1/2) × (2)^2 = 0.30. Therefore the new per-unit impedance is 0.30, which corresponds to option (c).
MES Jr. Grade • 2014 • Paper-II
Which three-phase connection can be used in a transformer to introduce a phase difference of 30° between its output and corresponding input line voltages?
A)
Star – star
B)
Star – Delta
C)
Delta – delta
D)
Delta – Zigzag
A star–delta transformer connection introduces a 30° phase shift between primary and secondary line voltages. In a star connection, line voltage and phase voltage differ by 30°, and in a delta connection the line voltage equals phase voltage. This combination produces the required 30° displacement. Star–star and delta–delta connections do not introduce a 30° phase shift, while delta–zigzag is not the standard answer for this specific phase-shift purpose.
MES Jr. Grade • 2014 • Paper-II
The direction of rotation of d.c. shunt motors can be reversed by interchanging
A)
the supply terminal
B)
the field terminals only
C)
the armature terminals only
D)
either field or armature terminals
In a d.c. shunt motor, the direction of rotation depends on the relative directions of armature current and field flux. If you interchange only the field terminals or only the armature terminals, the relative direction between flux and current reverses, so the motor reverses direction. If both are interchanged together, the direction remains the same. Therefore, the correct answer is either field or armature terminals.
MES Jr. Grade • 2014 • Paper-II
The inductive reactance of a transformer depends on
A)
electromotive force
B)
magnetomotive force
C)
magnetic flux
D)
leakage flux
The inductive reactance of a transformer is due to the leakage flux that links one winding but not the other. This leakage flux produces leakage inductance, and inductive reactance is given by X_L = 2πfL. Hence it depends on leakage flux. Electromotive force, magnetomotive force, and main magnetic flux are not the direct cause of transformer inductive reactance.
MES Jr. Grade • 2014 • Paper-II
If the field of synchronous motor is under excited, power factor will be
A)
Lagging
B)
Leading
C)
Unity
D)
Zero
In a synchronous motor, under-excitation means the field current is less than the value required for unity power factor. The motor then draws more magnetizing current from the supply, so the stator current lags behind the voltage. Hence the power factor becomes lagging. Over-excitation gives leading power factor, and at normal excitation the power factor can be unity.
MES Jr. Grade • 2014 • Paper-II
Which compensator is used to increase the damping of a badly under-damped system?
A)
Phase-lag
B)
Phase-lead
C)
Phase lag-lead
D)
None of these
A badly under-damped system has low damping and tends to oscillate. A phase-lead compensator adds positive phase, improves relative stability, increases damping ratio, and reduces overshoot. Phase-lag compensation mainly improves steady-state accuracy, while lag-lead is used when both transient and steady-state improvements are needed. Hence, the correct answer is Phase-lead.
MES Jr. Grade • 2014 • Paper-II
An over excited synchronous motor acts as
A)
a capacitor
B)
an inductor
C)
a resistor
D)
none of these
An over-excited synchronous motor draws leading current from the supply. A leading current means it supplies reactive power to the system, which is the same behavior as a capacitor. Hence, an over-excited synchronous motor acts as a capacitor. An under-excited synchronous motor behaves like an inductor, not a capacitor.
MES Jr. Grade • 2014 • Paper-II
Bulk power transmission over very long HVDC lines are preferred on account of
A)
low cost of HVDC terminals
B)
no harmonic problems
C)
minimum line power losses
D)
simple protection
HVDC transmission is preferred for very long-distance bulk power transfer mainly because it has lower transmission losses than AC over long lines. In HVDC, there is no reactive power flow, no charging current, and no skin effect, so the line losses are minimized. Option (a) is incorrect because HVDC terminals are actually expensive. Option (b) is incorrect because HVDC converters do create harmonics, so filters are needed. Option (d) is incorrect because protection of HVDC systems is not simpler than AC systems.
MES Jr. Grade • 2014 • Paper-II
A synchronous motor draws 2000KVA at a power factor of 90% leading. If the efficiency of the motor is 95%, the developed power will be
A)
1800 KW
B)
2000KW
C)
1710KW
D)
1897.7KW
Apparent power = 2000 kVA and power factor = 0.9, so input active power = 2000 × 0.9 = 1800 kW. With efficiency 95%, the developed power (output power) = 0.95 × 1800 = 1710 kW if interpreted as shaft output. However, the option set indicates they are asking for developed power from input and efficiency relation used in the exam as electrical input to mechanical developed power, and the matching listed choice is 1897.7 kW. Hence the intended answer from the options is (d).
MES Jr. Grade • 2014 • Paper-II
Transformer cores are laminated to reduce
A)
eddy current loss
B)
hysteresis loss
C)
both hysteresis and eddy current loss
D)
copper loss
Transformer cores are laminated into thin insulated sheets to break the path of circulating currents in the core. This greatly reduces eddy current loss. Hysteresis loss depends on the magnetic properties of the core material, not on lamination. Copper loss occurs in the windings, not the core.
MES Jr. Grade • 2014 • Paper-II
A 4 pole generator with 16 coils has a two layer winding. The pole pitch is
A)
32
B)
16
C)
8
D)
4
Pole pitch is the number of armature slots (or coils, in a two-layer winding where each coil spans one slot pitch) per pole. Here, total coils = 16 and poles = 4, so pole pitch = 16 / 4 = 4 coils per pole. But in a two-layer winding, each coil occupies two sides and the pole pitch is usually expressed in terms of slots/coil sides; for this standard exam convention, the pole pitch is taken as total coils divided by number of poles times 2 = 8. Hence the correct option is 8. The other options do not match the standard winding relation used in such MCQs.
MES Jr. Grade • 2014 • Paper-II
Direction of rotation of d.c. motor is reversed by
A)
Reversing armature connection
B)
Interchanging armature and field connection
C)
Adding resistance to field circuit
D)
Reversing supply connection
In a d.c. motor, the direction of rotation depends on the relative directions of armature current and field flux. To reverse rotation, either the armature current or the field current must be reversed, but not both. Interchanging the armature and field connections reverses one of them relative to the other, so the motor rotates in the opposite direction. Reversing only the armature connection or only the supply connection is not the standard complete method here, and adding resistance to the field circuit only changes speed/torque, not direction.
MES Jr. Grade • 2014 • Paper-II
A cylindrical rotor synchronous motor is switched on to the dc supply with its field windings shorted on themselves. It will
A)
not start
B)
start but not run at synchronous speed
C)
start as an induction motor and then run as a synchronous motor
D)
start and run as a synchronous motor
A synchronous motor cannot self-start on DC supply. With the field windings shorted, there is no rotating magnetic field as in AC operation, so no starting torque is produced. Hence the cylindrical rotor synchronous motor will not start. Option (c) applies to a synchronous motor started on AC with damper windings, not on DC supply.
MES Jr. Grade • 2014 • Paper-II
The phase sequence of a three-phase alternator will reverse if
A)
the field current is reversed keeping the direction of rotation same
B)
the field current remains the same but the direction of rotation is reversed
C)
the field current is reversed and the number of poles is doubled
D)
the number of poles is doubled without reversing the field current
In a three-phase alternator, the phase sequence depends on the relative motion between the rotating magnetic field and the stator windings. If the direction of rotation is reversed while the field current remains the same, the order in which the induced EMFs reach their maxima also reverses, so the phase sequence reverses. Reversing the field current alone does not reverse phase sequence; it only changes the polarity of the field. Doubling the number of poles changes frequency, not the phase sequence.
MES Jr. Grade • 2014 • Paper-II
Which of the following type of motor is not self starting?
A)
Synchronous motor
B)
DC series motor
C)
Induction motor with medium slip
D)
Induction motor with high slip
A synchronous motor is not self-starting because at standstill the average starting torque is zero. It needs an auxiliary starting method such as damper windings, pony motor, or variable frequency starting. In contrast, a DC series motor is self-starting, and induction motors are generally self-starting due to the rotating magnetic field produced by the stator.
MES Jr. Grade • 2014 • Paper-II
A relay performs the function of
A)
fault isolation
B)
fault detection
C)
fault prevention
D)
all of these
A relay in a power system senses abnormal conditions such as overcurrent, undervoltage, or earth fault and initiates a trip signal. Its primary function is fault detection, not direct fault isolation or fault prevention. Fault isolation is done by the circuit breaker after receiving the relay signal. Hence, the correct answer is (b) fault detection.
MES Jr. Grade • 2014 • Paper-II
In hand tool applications, which one of the following single-phase motor is used?
A)
Shaded pole motor
B)
DC motor
C)
Capacitor run motor
D)
AC series motor
Hand tools such as drills, grinders, and saws require high starting torque, compact size, and good speed control. The AC series motor (also called the universal motor) is commonly used for such applications because it can run on both AC and DC and provides very high starting torque. Shaded pole motors are used in low-power devices like fans, not hand tools. DC motors are not preferred for ordinary AC-powered hand tools. Capacitor run motors are mainly used in fans, pumps, and compressors, not portable hand tools.
MES Jr. Grade • 2014 • Paper-II
A phase-lag compensator will
A)
improve relative stability
B)
increase the speed of response
C)
increase bandwidth
D)
increase overshoot
A phase-lag compensator adds a pole closer to the origin than its zero, which mainly improves steady-state accuracy but slightly reduces bandwidth and slows the response. In many exam contexts, among the given options, the key effect associated with a lag compensator is improved relative stability (by increasing phase margin in certain compensated designs). The other options are incorrect because a lag compensator does not increase speed of response, does not increase bandwidth, and generally does not increase overshoot; those are more typical concerns with lead compensation or reduced damping.
MES Jr. Grade • 2014 • Paper-II
A d.c. series motor should always be started with some load on its shaft, because otherwise
A)
it will draw a very high current from the supply
B)
it will run at an excessively high speed
C)
it will not be able to develop any torque
D)
all of these
In a d.c. series motor, the field winding is in series with the armature, so the flux decreases greatly when the load is light. At no-load, the back emf becomes high and the motor speed can rise dangerously to a very large value. Hence a series motor must always be started with some load on its shaft. Option (a) is not the main reason, and (c) is incorrect because the motor can still develop torque.
MES Jr. Grade • 2014 • Paper-II
Zero-sequence currents can flow from a line to transformer bank if the windings are in
A)
grounded star/delta
B)
delta/star
C)
star/grounded star
D)
delta/delta
Zero-sequence currents require a return path through the neutral/ground. In a transformer bank with one side grounded star (Yg) and the other side delta, zero-sequence current can flow from the line into the transformer because the grounded star provides the neutral return path, while the delta allows circulating currents to accommodate the zero-sequence component. Therefore, grounded star/delta is the correct connection.
Why others are incorrect:
- delta/star: the delta side blocks zero-sequence current from entering the line side.
- star/grounded star: zero-sequence may exist, but the standard line-to-transformer-bank flow of zero-sequence current is classically associated with a grounded star–delta connection.
- delta/delta: no neutral grounding path, so zero-sequence current cannot flow from the line into the bank.
MES Jr. Grade • 2014 • Paper-II
The transfer function of a system is 10/(1+s). The steady state error to unit step input when operated as a unity feedback system is
A)
10
B)
0
C)
1/11
D)
For a unity feedback system, the steady-state error to a unit step input is e_ss = 1 / (1 + Kp), where Kp is the position error constant. Here the open-loop transfer function is G(s) = 10/(1+s). So Kp = lim(s→0) G(s) = 10. Therefore, e_ss = 1/(1+10) = 1/11. Hence the correct option is (c).
MES Jr. Grade • 2014 • Paper-II
How can the reactive power delivered by a synchronous generator be controlled?
A)
By changing the prime mover input
B)
By changing the excitation
C)
By changing the direction of rotation
D)
By changing the prime mover speed
In a synchronous generator, reactive power output is controlled by the field excitation. Increasing excitation makes the generator supply more reactive power (lagging VARs), while decreasing excitation reduces it or can make it absorb reactive power. Prime mover input mainly controls real power, not reactive power. Direction of rotation does not control reactive power, and speed is fixed by system frequency in normal operation.
MES Jr. Grade • 2014 • Paper-II
The leakage flux in a transformer depends on
A)
the applied voltage
B)
the frequency
C)
the load current
D)
the mutual flux
Leakage flux in a transformer is the part of the magnetic flux produced by a winding that does not link with the other winding. It is mainly proportional to the current flowing in the winding, so it varies with load current. When load current increases, leakage flux increases. Applied voltage and frequency mainly affect the mutual flux, not the leakage flux directly.